ITRON Water Flow Meter " WOLTEX WOLTEX Actaris ITRON Water Flow Meter, Flange Mounted for Industrial & Building, Size : 2 " - 20 " . And we can supply another Water Meter : Sensus....
" Accuracy : Â ± 5%
Max admissible Pressure : 20 Bar
Minimum scale interval graduated : 1L
Minimum scale interval read : 0, 5L
Max Working Temperature : 130Â º C
Indicating....
" Accuracy : Â ± 5%
Max admissible Pressure : 20 Bar
Minimum scale interval graduated : 5L
Max Working Temperature : 50Â º C
Indicating range : 9999999, 9 m ³
Flange Rating : ....
" Accuracy : 0.2%
Max Water Pressure : d1MPa/ 10 bar
Water Temperature : d50pC
Max Reading : 99999.9999 m ³
Min Reading : 0, 0001 m ³
Flowrange : 1, 5 - 3 ~ 6-12 m ³ / h
....
" Accuracy : 0.2%
Max Water Pressure : d1MPa/ 10 bar
Water Temperature : d30pC
Max Reading : 999999.99 m ³
Min Reading : 0, 1 m ³
Flange Rating : JIS 10 kgf/ cm ² FF
....
" Accuracy : 0.2%
Max Water Pressure : d1MPa/ 10 bar
Water Temperature : d30pC
Max Reading : 999999.99 m ³
Min Reading : 0, 1 m ³
Flange Rating : JIS 10 kgf/ cm ² FF
....
" Accuracy : 0.2%
Max Water Pressure : d1MPa/ 10 bar
Water Temperature : d30pC
Max Reading : 999999.99 m ³
Min Reading : 0, 1 m ³
Flange Rating : JIS 10 kgf/ cm ² FF
....
" Accuracy : 0.2%
Max Water Pressure : d1MPa/ 10 bar
Water Temperature : d40pC
Max Reading : 99999 m ³
Min Reading : 0, 0001 m ³
Flowrange : 1.5 - 3 ~ 15-30 m ³ / h
Type ....
" Accuracy : 0.2%
Max Water Pressure : d1MPa/ 10 bar
Water Temperature : d40pC
Max Reading : 999999.99 m ³
Min Reading : 0, 0001 m ³
Flange Rating : JIS 10 kgf/ cm ²
....
" Measurement accuracy : + / - 2% on flows
Operating temperature Cold Water: 122' F ( 50pC)
Process Connection : ANSI 150lb RF Flange ( Standard)
and 300lb RF Flange ( ....
Measurement accuracy : + / - 2% on flows
Measures Hot Water : 266' F ( 130p C)
Process Connection : ANSI 150lb RF Flange ( Standard)
and 300lb RF Flange ( Optional)
Measurement accuracy : + / - 2% on flows
Measures Hot Water : 104 F ( 40p C)
Process Connection : ANSI 300lb RF Flange / DIN PN-25/ 40

Hub : PD. Ninggala Berkat Abadi telp : ....
Measurement accuracy : + / - 2% on flows
Measures Hot Water : 266 F ( 130p C)
Process Connection : ANSI 300lb RF Flange / DIN PN-25/ 40

Hub : PD. Ninggala Berkat Abadi telp ....