Servosystems Trainer ( DC motors)[12 Jan. 2011, 2:09:09]
HargaCompetitive (Call)
Jumlah Pesanan:
Jumlah-
Kemas & PengirimanBox
Servosystems Trainer ( DC motors)
adalah alat peraga untuk mempelajari sistem tenaga Servo rendah.

SPECIFICATION

The trainer includes:
Base Unit:

* Steel box,
* Diagram in the front panel with similar distribution that the elements in the real unit.
* Electromechanic unit.
* Tachometric adaptor.
* Generation and control of set point.
* Ramp generator, as well as sinusoidal, triangular and square wave generator.
* PWM modulator.
* Open loop control.
* Close loop control:
* Proportional Control ( P) .
* Integrative Proportional Control ( PI) .
* Proportional derivative Control ( PD) .
* Proportional Integrative derivative control ( PID) .
* Current limiter.
* Turn inversion control.
* Stop/ starting control.
* Power stage and excitation of the power stage.
* Brake control.
* Fault simulator that allows the entries of a considerable amount of disfunctions in order to the students diagnose its nature and find
* out the components that cause them. Without taking risks to provoke any damage in the unit.
* Type of faults included in the unit:
* Fault 1: The absolute value of the feedback signal from the tachogenerator is not calculated for its subtraction from the
* reference, thus, for one of the turning senses, the error is wrong.
* Fault 2: The value of the Proportional constant of the PID is divided by ten with the user unable to detect it but its effect.
* Fault 3: The value of the Integral constant of the PID is divided by ten with the user unable to detect it but its effect.
* Fault 4: The value of the Derivative constant of the PID is divided by ten with the user unable to detect it but its effect.
* Fault 5: The signal from the tachogenerator is modified, making the PID control to believe that the speed is ten times lower to
* the real one.
* None of these faults are exclusive, being possible to combine them.
* Direct current motor ( DC) and tachometric generator.
* Computer Control Software.
* Cables and accessories, necessary for its correct operation.
* Manuals:
* This unit is supplied with several manuals: Required Services, Assembly and Installation, Starting-up, Safety, Interface and Control Software,
* Maintenance, Calibration & Practices and simulation of faults Manuals.

Untuk informasi lebih lanjut dan pemesanan :

Silakan hubungi sales consultant, Hotline kami di ( 021) 8611444

Distributor, Agent, Penjualan, Pemasangan dan Training.
Jakarta - Indonesia

Kontak Person: Syafei ( 0815 614 1954 / 0811 893 101)
Alamat: Jl. Pahlawan Revolusi No. 22B
Telp. + 62-21-8611 131, 8611 259, 8611 444, 8611449
Fax : + 62-21-8611 207
EMAIL : sales@ alatperaga.com

Kunjungi Website kami : www.alatperaga.com
Anda mendapat [3] permintaan baru.Ke Menu Anggota © 2024 Indotrade.co.id. Hak Cipta Dilindungi Undang-undang.