Stenner 170DM5 | Stenner 170JL5C3SWAA | 08188 07696 | Stenner 170DM5 | Stenner 170JL5C3SWAA | Stenner 170DM5 | Stenner 170JL5C3SWAA | Stenner 170DM5 | Stenner 170JL5C3SWAA | Stenner 170DM5 | Stenner 170JL5C3SWAA | Stenner 170DM5 | Stenner 170JL5C3SWAA | Stenner 170DM5 | Stenner 170JL5C3SWAA | Stenner 170DM5 | Stenner 170JL5C3SWAA | Stenner 170DM5 | Stenner 170JL5C3SWAA | Stenner 170DM5 | Stenner 170JL5C3SWAA | Stenner 170DM5 | Stenner 170JL5C3SWAA
Double Head Fixed Output Metering Pump - 170DMP5 Classic Series From Stenner
Double Head Fixed Output Metering Pump
25 psi ( 1.7 bar)
max 170 gpd ( 644 lpd)
How It Works
Stenner’ s double head fixed output metering pump is built with three detachable components: the motor and two pump heads. Outputs are dependent upon the rpm of the motor gears and the size of the peristaltic pumping tubes. All Stenner metering pumps have a 3-point roller design in the pump head, which acts as a check valve to prevent back flow, siphoning, overdosing and loss of prime.
The motor shaft rotates at a fixed rpm which drives the adjustable feed rate control to intermittently engage the roller assembly within the pump heads. The chemical solution in the pumping tube is captured between the rollers as they rotate and compress the tube. As the rollers advance, the squeezed tube section regains its original form and generates a vacuum, creating the self- priming feature that delivers a constant flow unaffected by the outlet pressures.
Advantages
Self-priming up to 25 feet and does not lose prime
Can pump off-gassing solutions
Solutions contained in tube, not exposed to pump components or air
Subassemblies fit together without tools; easy service or conversion to another model
Pump head universal to all Stenner pumps
Can run dry without damage
Will not clog from dirt or debris
Reproducible outputs within 2%
Adjustable feed rate control from 5% -100% in 2.5% increments
Pump tubes accept a variety of chemicals
170DMP5 Classic Series Specifications Summary
Outputs @ 60Hz
Gallons per day: 170.0
Gallons per hour: 7.08
Liters per day: 643.6
Liters per hour: 26.8
Ounces per minute: 15.10
Milliliter per minute: 446.88
Outputs @ 50Hz
Liters per day: 514.8
Liters per hour: 21.45
Milliliters per minute: 357.50
Discharge Pressure
0-25 psi ( 0-1.7 bar)
Voltage
120V 60Hz; 220V 60Hz
230V 50Hz; 250V 50Hz International
Motor
shaded pole; 44 rpm; 1/ 30 HP
Suction Lift
25' ( 7.6 m)
Maximum Operating Temperature
125° F ( 52° C)
Amp Draw
1.7 120V; 0.9 220V, 230V, 250V
Dimensions ( l x w x h)
10.2 x 5.3 x 6.0 in
( 25.9 x 5.3 x 6.0 cm)
Shipping Weight
9 lbs ( 4 kg)
Materials of Construction
All Housings: Lexan® polycarbonate plastic
Pump tube: Santoprene® FDA approved
Pump tube: Tygothane® FDA approved
Suction/ discharge tubing & ferrules ( 1/ 4" & 6 mm) : LDPE polyethylene,
NSF/ FDA approved
Tube fittings, connecting nuts, check valve fitting,
weighted strainer: Type 1 Rigid PVC-NSF listed
All fasteners: Stainless Steel
Lexan® is a registered trademark of General Electric.
Santoprene® is a registered trademark of Advanced Elastomer system
Tygothane® is a registered trademark of Saint-Gobain Performance Plastics
Pellathane® is a registered trademark of The Dow Company
Agency listings
Santoprene® : UL, CSA , CE, NSF-61
Tygothane® : UL, CSA, CE
Accessories shipped with each pump
6 connecting nuts 1/ 4" or 3/ 8"
6 ferrules 1/ 4" & 6 mm OR 2 ferrules 3/ 8"
2 injection fittings
2 weighted strainer
2 20' roll of suction/ discharge tubing 1/ 4" or 3/ 8" white or UV black
OR 6 mm ( Europe) white
2 spare pump tube
1 mounting bracket
1 installation manual