Selamat Datang di
Pd Karya Agung Indonesia

Anggota Gratis
Pd Karya Agung Indonesia
Indonesia
  • Jual

    BIOLOGICAL SAFETY CABINET CLAS II-1500II 2-X,  FUME HOOD LEMARI ASAM. Hub Mia 0856 9139 8333. Email : Pdkaryaagungindonesia@ yahoo.com

    BIOLOGICAL SAFETY CABINET CLAS II-1500II 2-X, FUME HOOD LEMARI ASAM. Hub Mia 0856 9139 8333. Email : Pdkaryaagungindonesia@ yahoo.com

    Harga:
    Bersaing
    Jumlah Pesanan:
    Negara Asal:
    Amerika Serikat
    Cara Pembayaran:
    Tunai
    Jumlah:
    Banyak
    Kemas & Pengiriman:
    Unit
    The Class II Biological Safety Cabinet is designed with inward air flow at a velocity to protect personnel, HEPA-filtered vertical laminar airflow for product protection, and HEPA-filtered exhausted air for environmental protection.

     Airflow System:
    70% air recirculation
    30% air exhaust
    Maintain a minimum average inflow velocity is 0.65 m/ s and average downflow velocity is 0.37 m/ s

    * Biological Safety Cabinet
    * Laminar Airflow
    * Fume Hood
    * Analyzers
    * Cold Chain
    * Purifying Solutions
    * Lab Waste Solutions

    Air safety solotions QRJ-168

     Function and Operating Principle

    The Class II Biological Safety Cabinet is designed with inward air flow at a velocity to protect personnel, HEPA-filtered vertical laminar airflow for product protection, and HEPA-filtered exhausted air for environmental protection.

    BSC-1500IIA2-X is designed to meet the operating principles:

    BSC-1500IIA2-X is designed to meet the performance criteria:

    1.US Standard ANSI/ NSF 49: 2002
    2.European Standard EN13469: 2000
    3.Chinese Standard YY0569-2005

     Airflow System:

    70% air recirculation
    30% air exhaust
    Maintain a minimum average inflow velocity is 0.65 m/ s and average downflow velocity is 0.37 m/ s

     Configuration

    ` Front panel. It s made of toughened glass, which can not be caused negative effect by cleanliness and sterilization. Thickness of front panel is no less than 5mm. The structure of front panel avoids danger to operator when suspended system cannot work correctly. Audible and visual alarm are activated when the window exceeds height range of 200mm± 5mm.

    aUV light. UV interlock provides additional safety by prohibiting UV light operation unless the front window is fully closed.

    bRemote control. The operator need not to contact the biological safety cabinet directly, it s favorable for preventing cross contamination. It also makes the control operation much easier and convenient. ( See Figure 3 )

    cBase stand and footrest. Burliness, simple design, no uncovered screw thread. Both of them can adjust the horizontality and stability of cabinets. Space between cabinet and floor makes cleaning easier.

    dCollecting Tank. The capacity of the collecting tank is no less than 4000ml, which is used to collect the spatters of work area and there is no obvious leak and pervasion within one hour. One drain valve under collecting tank and it is convenient for cleanliness.

    eFoot Switch. Within the range of the activity, we could use foot switch to adjust the height of the front panel.

    fVFD Control Panel. ( See Figure 4)

    gPower Switch.

    hPower Socket.

    iAir Grill. Air will be drawn into the cabinet through the air grill.

    ~ Water tight socket. Two single water tight sockets are provided on the sidewall for small devices or equipment used within the cabinet.

     The filter replacement and blower maintenance can be finished on the front of the cabinet
     Safety Features

    Ã Cabinet Leak Test. Biobase cabinets have to pass pressure decay test as defined in the European Standard 2469: 2000, US Stand ANSI/ NSF 49: 2002 and Chinese Standard YY0569-2005

    Ã KI-Discus Containment Test. Biobase cabinets are tested using the KI-Discus method according to European Standard EN12469: 2000 and Chinese Standard YY0569-2005 for containment and operator safety at the manufacturing site.

    Ã Filter Leak Test. Biobase cabinet are tested using an aerosol photometer according to European Standard 2469: 2000, US Stand ANSI/ NSF 49: 2002 and Chinese Standard YY0569-2005. This test determines the integrity of down-flow and exhaust filters, filter housings and filter mounting frames.

    Ã Automatic self-filtering cycle at start-up requires a fixed period of warm-up period during which the cabinet work zone is purged of contaminants before use

    Ã Intrinsically-safe negative pressure design

    à The motor/ blower system is able to compensate automatically to maintain the down-flow air at the speed of 0.37± 0.015 without interruption to guarantee the safe performance.

    Ã Interlocked UV light only operates when blower and fluorescent light are off and sash is closed.

    Ã Front window glass is toughened glass ( standard) or non-reflecting multi-layer safety glass ( optional) , which provides enhanced UV protection for operators

    Ã Audible and visual alarms prompt the operator in case of any unsafe condition.

     Performance Features

    Ã HEPA Filter 99.999% efficient ( 0.3 microns ) . HEPA filter is constructed of pleated borosilicate glass fibers.

    Ã HEPA Filter ( Standard for Manual Window Series) 99.999% efficient( 0.3 microns) HEPA filter is constructed of pleased borosilicate glass fibers.

    Ã Filter Life Indicator. The pressure value is displayed on the control panel to show the life utility of the main filter and exhaust filter

    Ã A microprocessor control system, together with LED display makes it clear for all control and safety functions, Intelligent diagnostics of problems.

    Ã True airflow velocity ( both down-flow and inflow) sensing technology, with temperature compensation for improved sensor accuracy. The velocity value continuous digital display on the front LED for constant monitoring.

    Ã UV timer function to control the decontamination cycle and maximize lamp life.

    Ã Easy to decontaminate and disinfect. The working chamber of the safety cabinet is easy to be cleaned and disinfected. The stainless steel counter surface can be took out for autoclaving

    Ã Weight-balanced Front Window

     Ergonomic Features

    Ã 10 degree sloped front enhanced mobility and depth of reach into the work area, also provides maximum protection.

    Ã Control panel is sloped downwards to provide the operator ( in a setting position) a better view of and an easier access to the controls.