Keterangan :
Water Meter
WP-Dynamic
Flow Sensor For Hot Water up to 130° C
DN 80
Flow Sensor Rate Pressure PN 40
Technical Data
Performance Data WP-Dynamic 130° C
Nominal Diameter : DN 80
Qmax : 90 m³ / h
Maximum peak flow
once lifetime 24h Qmax
or 5 min. 1.2 x Qmax
Qn-Continuous Flow ( ± 2% ) : 45 m³ / h
Qt-Transitional Flow ( ± 2% ) : 3.2 m³ / h
Qmin-Minimum Flow ( ± 5% ) : 1.4 m³ / h
Starting Flow : 0.35 m³ / h
Performance data table according to PTB-A22 spesification class B
Diameter Nominal DN : 80 mm
Size of meter ( acc. to PTB-A-22) Qn : 40
Qmax-Maximum peak flow short time : 80 m³ / h
Qn-Continuous Flow ( ± 3% ) : 40 m³ / h
Qt-Transitional Flow ( ± 3% ) : 6.0 m³ / h
Qmin-Minimum Flow ( ± 3% ) : 1.6 m³ / h