Jual: DIJUAL PENDOSE 200 radiac meter im-264 ( JUAL SURVEYMETER, PENDOSE, TLD, ALAT PROTEKSI RADIASI) :
The advanced PEN direct reading dosimeters are rugged, precision instruments. They are higher quality and have greater reliability than other dosimeters of this type. They measure and directly read, at any time, accumulated dose ( quantity of gamma and x-ray exposure) . PEN dosimeters are designed to satisfy military specifications for the RADIAC METER IM-264/ PD and ANSI N 13.5 and N322 requirements. A sturdy metal clip attaches the dosimeter to a pocket or any object to monitor total radiation exposure. They are hermetically sealed and immersion proof.

Specifications:
Exposure Range ( gamma and x-rays)
PEN200mR Scale increments of 10mR
PEN500mR Scale increments of 20mR
PEN2R increments of 100 mR
PEN5R increments of 200mR
PEN20R increments of 1R
PEN2mSv increments of .1mSv
PEN5mSv increments of .2mSv
National Stock Numbers Available

Energy Dependence:
± 10% maximum change in sensitivity for x and gamma ray energies from 16 keV to 8 MeV.

Electrical Leakage:
In the absence of radiation, the dosimeters leakage or self discharge is less than 0.5% of full scale in 24 hours at 50° C. At 20° C dosimeters will read background radiation. After gross over exposure totaling up to 2000 R the leakage is less than 5% of full scale in 48 hours at 20° C. Thereafter, the leakage will decrease to original values.

Charging Voltage:
Dosimeters are capable of being charged to " zero" with 140 to 195 volts.
Operational Characteristics

A maximum change in sensitivity of ± 10% may occur under any probable combination of the following:

A) Temperature range below -20° C ( -4° F) or above + 50° C ( 122° F)
B) Greater than 50, 000 foot altitude for one month
C) Relative humidity greater than 95% Highly resistant to shock and vibration.

Accuracy:

± 10% of true dose for Cs-137 or Co-60 gamma.

Rate Response:
Dosimeters are dose rate independent.

Enclosure Material:
Barrel - carbon fiber-filled, high-strength, electrically-conducting plastic with metal clip.

Weight:
Approx. 19 grams ( 0.7 oz.)

Size:
PEN- 200, 500
2mSv, 5mSv Length: 11 cm ( 4.48 inches)

Diameter: 1.5 cm ( 0.6 inches)

PEN- 2, 5, 20 Length: 11.5 cm ( 4.52 inches)
Diameter: 1.5 cm ( 0.6 inches)
Options
Protective sapphire lens
Warranty
2 year limited warranty

PRICE:
Rp 4.500.000, 00/ unit ( ready stok)
HARGA SUDAH TERMASUK KALIBRASI PERTAMA KALI DAN TIDAK KENA TAMBAHAN PPN 10 % .

: : harga bisa berubah sewaktu-waktu tanpa ada pemberitahuan sebelumnya.

Untuk informasi lebih lengkapnya silahkan hubungi saya di 087836837227, 085861900600, 081393499641 an. GHULAM FATHUL AMRI atau email di ghulamzuhri@ yahoo.com

JIKA TIDAK BERKEBERATAN, MAKA SAYA AKAN SANGAT BERTERIMA KASIH JIKA ANDA MEMBANTU SAYA MENYEBARKAN PESAN INI KE REKAN-REKAN / KOLEGA ANDA YANG SEKIRANYA MEMBUTUHKAN BARANG KAMI.
Negara Asal:Amerika Serikat
Harga:Rp 3.500.000,00 PER BUAH
Cara Pembayaran:Tunai
Jumlah:SATUAN-TERSERAH YANG BELI
Kemas & Pengiriman:DUS

Anda mendapat [3] permintaan baru.
Ke Menu Anggota

Depan - Penawaran Dagang - Daftar Produk - Daftar Permintaan - Daftar Kerjasama - Daftar Perusahaan
© 2024 Indotrade.co.id. Hak Cipta Dilindungi Undang-undang.