Anggota Gratis
geologistsurvey
Informasi Kontak
Nama:
Tn. Aries Setiawan [Pemasaran]
E-mail:
Situs Web:
Pesan Instan:

Nomor Telpon:
Nomor telpon Tn. Aries Setiawan di TANGERANG
Nomor Ponsel:
Nomor ponsel Tn. Aries Setiawan di TANGERANG
Nomor Faks:
Nomor faks Tn. Aries Setiawan di TANGERANG
Alamat:
Raya ciledug Larangan Indah. JL Muhasim Rt 01/001 No.25
TANGERANG 15154, Banten
Indonesia
Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

xxxx
Produk Terbaru
Bahasa :
penakar curah hujan OBS sertifikat BMKG
penakar curah hujan....

Katalog Produk

Total Station Nikon NPL 632, hub 0857 1133 8980[17 Aug. 2010, 3:21:32]
HargaNEGO
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T), Tunai
Kemas & PengirimanBOX
Kenalkan ke teman Anda
Keterangan
The DTM-652 Total Station is one of the fastest total stations in its class, with highly accurate 1" angle and 2+ 2ppm distance measurement capabilities. This EDM helps you move quickly through your survey routines, so you spend less time in the field.

DTM-652 offers long battery life of 10 hours ( 6 hours for NPL-632) continuous distance/ angle measurement, or 27 hours ( 12 hours for NPL-632) with one distance measurement every 30 sec.

DTM-652 Total Station and NPL-632 Pulse Laser Station cleared IP54 standard for dust and water resistance.

Survey software program installed on the DTM-652 and NPL-632 succeeds the DTM-502 series Total Station software which has been well-known as a easy-to-use and easy-to-learn software. For details of the software program.

DTM-652 NPL-632
Telescope
Tube length 158mm ( 6.22ft) 153mm ( 6.02in)
Image Erect
Effective diameter of objective 45mm/ 1.77in
( EDM: 50mm/ 1.97in) 40mm/ 1.57in
( EDM: 50mm/ 1.97in)
Magnification 33x 26x
Field of view 1° 20' 1° 30'
Resolving power 2.5" 3"
Minimum focusing distance 1.3m ( 4.26ft) 1.6m ( 5.3ft)
Reticle illumination Provided ( 3 steps)
Distance measurement ( with Nikon specified prism)
Under good conditions
with reflector sheet ( 5 x 5 cm) 5 to 100m / 16.4 to 328.1ft 1.6 to 300m / 5.3 to 980ft
With mini prism 1100m / 3600ft 1.6 to 3000m / 5.3 to 9800ft
With single prism 2700m / 8900ft 1.6 to 5000m / 5.3 to 16400ft
With triple prism 3600m / 11800ft -
With nine prisms 4400m / 14400ft -
Under normal conditions
with reflector sheet ( 5 x 5 cm) 5 to 100m / 16.4 to 328.1ft 1.6 to 300m / 5.3 to 980ft
With mini prism 950m / 3100ft 1.6 to 3000m / 5.3 to 9800ft
With single prism 2400m / 7900ft 1.6 to 5000m / 5.3 to 16400ft
With triple prism 3100m / 10200ft -
With nine prisms 3700m / 12100ft -
Reflectorless mode
( white target) * 1 - 1.6 to 210m / 5.3 to 680ft
Readout display 9999.9999m / 29999.999ft
Accuracy
Precise mode ± ( 2+ 2ppm x D) mm ± ( 3+ 2ppm x D) mm
± ( 3+ 3ppm x D) mm
Normal mode ± ( 4+ 2ppm x D) mm ± ( 5+ 10ppm x D) mm
Least count
Precise mode 0.1/ 1mm, 0.0005ft/ 0.002ft
Normal mode 1/ 10mm, 0.002/ 0.02ft
Measuring intervals ( DTM-652) * 2
Precise mode 1.0 sec ( initial: 1.0 sec) -
Normal mode 0.5 sec ( initial: 1.0 sec) -
Measuring intervals ( NPL-632) * 2
Prism mode ( Precise mode) - 1.3 sec ( initial: 2.0 sec)
Prism mode ( Normal mode) - 0.5 sec ( initial: 1.6 sec)
Reflectorless ( Precise mode) - 1.6 sec ( initial: 2.6 sec)
Reflectorless ( Normal mode) - 0.8 sec ( initial: 2.0 sec)
Ambient temperature range – 20° C to 50° C / – 4° F to + 122° F
Atmospheric correction
Temperature range -40° C to 60° C / -40° F to 140° F
Barometric pressure 400 to 999mmHg/ 533 to 1, 332hPa/ 15.8 to 39.3 in.Hg
Prism offset correction -999 to + 999
Angle measurement
Reading system Photoelectric detection by incremental encoder
( diametrical detection for H/ V circles)
Circular diameter 79mm
Minimum increment
( Degree) 0.5" / 1" / 5" 1" / 5" / 10"
( Gon) 0.1mgon/ 0.2mgon/ 1mgon 0.2mgon/ 1mgon/ 2mgon
( MIL6400) 0.002mil/ 0.005mil/ 0.02mil 0.005mil/ 0.02mil/ 0.05mil
Accuracy 1" / 0.3 mgon 2" / 0.5 mgon
Dual-axis compensator
Method Liquid electric detection, Dual-axis
Compensation range ± 3'
Setting accuracy ± 1"
Lumi-Guide
Working range 100m / 330ft
Positioning accuracy within approx. 6cm / 2.4in at 100m/ 330ft
Level vials
Sensitivity of plate level vial 30" / 2mm
Sensitivity of circular level vial 10' / 2mm
Optical plummet
Image Erect
Magnification 3x
Field of view 5°
Focusing range 0.5m / 1.6ft to
Display
Type Graphic LCD ( 128 x 64 dot) on both side
Point memory
Raw/ coordinates 10, 000 records
External memory device CompactFlash ( CF) card, USB memory
Environmental specification IP54
Dimensions( approx.) 166 x 168 x 365mm / 6.5 x 6.6 x 14.4in
Weight
Main unit 5.3 kg / 11.7lbs 5.3 kg / 11.7lbs
BC-80 0.6 kg / 1.3lbs
Operating time DTM-652 Approx. 10 hours
( continuous distance/ angle measurement)
Approx. 27 hours
( distance / angle measurement evey 30 seconds)
Approx. 28 hours ( angle measurement)
NPL-632 Approx. 6 hours
( continuous distance/ angle measurement)
Approx. 12 hours
( distance / angle measurement evey 30 seconds)
Approx. 25 hours ( angle measurement)
battery caarger for BC-80/ 65
Recharging time Approx. 3.0 hours for full recharge

Complete with:

* Nikon Total Station
* 2 x Aluminium Tripod
* 1 x Prisma Polygon
* 1 x Range Pole
* 1 x Single Prism
* 1 x Cable Data
* 1 x Software Data

http: / / www.geologistsurvey.indonetwork.co.id

mail/ ym: setiawan_bataviasurvey@ yahoo.co.id

Hub : Aris Setiawan

Hp : 0857 1133 8980

Telp : 021-7334444

Fax : 021-7318569
Anda mendapat [3] permintaan baru.
Ke Menu Anggota
Depan - Penawaran Dagang - Daftar Produk - Daftar Permintaan - Daftar Kerjasama - Daftar Perusahaan