BINDER - DRYING OVEN
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Negara AsalJerman
ED : Drying ovens with natural convection
Reliable drying and sterilization tasks, precise warm storage.
Performance features and equipment:
� Electronically-controlled APT.line preheating chamber technology with natural convection
� Temperature range of 5C above ambient temperature up to 300' C
� DS-controller with integrated timer 0 to 99 hours
� Digital temperature setting with degree accuracy
� One ramp function
� Adjustable safety device, Class 2 ( DIN 12880) , with visual temperature alarm
� Adjustable ventilation by means of rear exhaust duct 0 50 mm with ventilation flap and front ventilation slide
� 2 chrome-plated shelves
� Units up to 115 liters are stackable
� Optional RS 422 interface for communication software APT-COM DataControlSystem

The BINDER ED series
ED 23
ED 53
ED 115
ED 240
ED 400
ED 720

FD : Drying ovens with forced convection
Drying and sterilization tasks with reduced processing times.
Performance features and equipment:
� Electronically-controlled APT.line preheating chamber technology with forced convection
� Temperature range of 5' C above ambient temperature up to 300' C
� DS-controller with integrated timer 0 to 99 hours
� Digital temperature setting with degree accuracy
� One ramp function
� Adjustable safety device, Class 2 ( DIN 12880) , with visual temperature alarm
� Adjustable ventilation by means of rear exhaust duct 0 50 mm with ventilation flap and front ventilation slide
� 2 chrome-plated shelves
� Units up to 115 liters are stackable
� Optional RS 422 interface for communication software APT-COM DataControlSystem

Only at BINDER: Precision regardless of size - the 20-liter bench-top units

FD series
FD 23
FD 53
FD 115
FD 240

FED : Drying ovens with forced convection and multifunctional control
Universal performance for high-precision thermal processing via expanded time functions, including standard APT-COM DataControlSystem interface.
Performance features and equipment:
� Electronically-controlled APT.line preheating chamber technology with forced convection
� Temperature range of 5' C above ambient temperature up to 300' C
� MS-controller with several timer functions
� Controller timer functions: delayed ON, delayed OFF, temperature dependent delayed OFF
� Digital temperature setting with degree accuracy
� One ramp function
� Adjustable fan speed ( 0 to 100% )
� Adjustable safety device, Class 2 ( DIN 12880) , with visual temperature alarm
� Adjustable ventilation by means of rear exhaust duct 0 50 mm with ventilation flap and front ventilation slide
� 2 chrome-plated shelves
� Units up to 115 liters are stackable
� RS 422 interface for communication software APT-COM DataControlSystem, or switch over printer output with RS 232/ RS422 interface converter
� Adjustable intervals for printer

FED series
FED 53
FED 115
FED 240
FED 400
FED 720

FP : High-precision temperature test chamber for thermal cycling tests
Realization of demanding thermal cycling tests through comprehensive programming.
Performance features and equipment:
� Electronically-controlled APT.line preheating chamber technology with forced convection
� Temperature range of 5' C above ambient temperature up to 300' C
� MP-controller with 2 programs with 10 sections each, alternatively 1 program with 20 sections
� The time interval of single program sections can be adjusted up to a maximum of 99: 59 hours or 999: 59 hours. This adjustment applies to all program sections
� Program controller timer functions: delayed ON, delayed OFF, temperature dependent delayed OFF
� Adjustable ramp functions via program editor
� Adjustable fan speed ( 0 to 100% )
� Elapsed time indicator
� Adjustable safety device, Class 2 ( DIN 12880) , with visual alarm
� Adjustable ventilation by means of rear exhaust duct 0 50 mm with ventilation flap and front ventilation slide
� 2 chrome-plated shelves
� Units up to 115 liters are stackable
� RS 422 interface for communication software APT-COM DataControlSystem, or switch over printer output with RS 232/ RS422 interface converter
� Adjustable intervals for printer
FP series
FP 53
FP 115
FP 240
FP 400
FP 720
rlhsrehjayana@yahoo.com