Anggota Gratis
PT. ANDALAN BANGUN SEJAHTERA
http://indotrade.co.id/andalbangunsejahtera/
\"JENCO INSTRUMENT - JEKEN Ultrasonic Cleaner - MITECH Ultrasonic thickness - DAVIS Weather Station - EUTECH Instrument - SOCOREX Liquid Handling - MEMMERT - BLUE GIZMO Instrument - HACH - OHAUS Balance - VITLAB Plasticware - DURAN Glassware - KETT
Informasi Kontak
Nama:

Ibu Pera / Krisna / Juni [Pemasaran]

E-mail:
Nomor Telpon:

Nomor telpon Ibu Pera / Krisna / Juni di Jakarta Pusat

Nomor Ponsel:

Nomor ponsel Ibu Pera / Krisna / Juni di Jakarta Pusat

Nomor Faks:

Nomor faks Ibu Pera / Krisna / Juni di Jakarta Pusat

Alamat:

Jl. Sumur Batu Raya No. 1 RT 001 RW 006, Kemayoran
Jakarta Pusat 10640, Jakarta
Indonesia

Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan
Bahasa :

Jual

HACH 2100Q Portable Turbiditymeter[5 Dec. 2010, 22:14:41]
HargaInquiry
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Jumlah1 unit
Kemas & Pengirimanper unit & franco Jabodetabek
Negara AsalAmerika Serikat
Model : 2100 Q
cat. : 2100Q01

The industry' s best portable turbidimeter just got better!

Meets EPA Method 180.1

* Single-standard RapidCalTM calibration offers the simplest solution for low-level measurements.
* Single-step verification and on-screen assisted calibration eliminates the need to reference complicated manuals.
* Optional USB+ Power Module ( LZV813) enables simple data transfer. All data is easily downloaded to any computer, providing superior data integrity and availability.
* Exclusive algorithm in the Rapidly Settling TurbidityTM mode provides accurate, repeatable measurements for rapidly settling, difficult-to-measure samples while eliminating the need for redundant measurements and estimating.

Hach portable turbidimeters are supplied with four AA alkaline batteries, a carrying case with insert, StablCal primary calibration standards in 1" sealed vials ( 20, 100, 800 NTU) , a 10 NTU primary verification standard, 6 sample cells with screw-tops, instrument manual ( printed and on CD-ROM) , quick start guide, silicone oil and oiling cloth.

Specifications

Measurement Method Ratio turbidimetric determination using a primary nephelometric light
scatter signal ( 90° ) to the transmitted light scatter signal
Regulatory Meets EPA Method 180.1
Lamp Source Tungsten filament lamp
Range 0-1000 NTU
Accuracy ± 2% of reading plus stray light from 0-1000 NTU
Repeatability ± 1% of reading or 0.01 NTU, whichever is greater
Resolution 0.01 NTU on lowest range
Stray Light = 0.02 NTU
Signal Averaging Selectable on or off
Detector Silicon Photodiode
Reading Modes Normal ( Push to Read)
Signal Averaging
Rapidly Settling Turbidity( TM)
Calibration Options Single step RapidCal( TM) for low-level regulatory reporting from 0-40 NTU
Full range calibration from 0-1000 NTU
Calibration to degrees of turbidity
Calibration Logger Records the last 25 successful calibrations
Verification Logger Logs the last 250 successful verifications
Data Logger 500 records
Power Requirement AC 100-240 V, 50/ 60 Hz ( with optional Power or USB+ Power Module)
4 AA alkaline batteries
Rechargeable NiMH ( with optional USB+ Power Module)
Operating Conditions Temperature: 0 to 50 ° C ( 32 to 122 ° F)
Relative Humidity: 0-90% at 30 ° C, 0-80% at 40 ° C, 0-70% at 50 ° C noncondensing
Storage Conditions -40 to 60 ° C ( -40 to 140 ° F) , instrument only
Interface Optional USB
Sample Required 15 mL ( 0.5 oz.)
Sample Cells Round cells, 60 x 25 mm ( 2.36 x 1 in.) , borosilicate glass with screw caps
Dimensions 22.9 x 10.7 x 7.7 cm ( 9.0 x 4.2 x 3.0 in.)
Weight 530 g ( 1.17 lb) without batteries
620 g ( 1.37 lb) with four AA alkaline batteries
Meter Enclosure Rating IP67 ( closed lid, battery and module compartment excluded)
Protection Class Power supply: Class II
Certification CE certified
Warranty 1 year
Anda mendapat [3] permintaan baru. Ke Menu Anggota
Depan - Penawaran Dagang - Daftar Produk - Daftar Permintaan - Daftar Kerjasama - Daftar Perusahaan
© 2024 Indotrade.co.id. Hak Cipta Dilindungi Undang-undang.